Temperature: |
Operating |
-40°C to +71°C |
|
|
Nonoperating |
-40°C to +71°C |
Thermal Shock: In accordance with MIL-STD-202, method 107, test condition A, except -40°C to +71°C.
Altitude: Sea level to 50,000 ft.
Shock: In accordance with MIL-STD-202, method 213, test condition B, 75’Gs.
Vibration: In accordance with MIL-STD-202, method 204, test condition B, (10-2,000Hz).
Moisture Resistance: In accordance with MIL-STD-202, method 106 as modified by MIL-PRF-22885F.
Fungus: In accordance with MIL-STD-454, requirement 4.
Salt Spray: In accordance with MIL-STD-202, method 101, test condition A.
Explosion: In accordance with MIL-STD-202, method 109.
DO-160D ELECTRICAL ENVIRONMENTAL CONDITIONS:
Magnetic Effect: In accordance with Section 15, equipment Class A.
Power Input: In accordance with Section 16, Category Z (28VDC) Normal 18VDC to 30.3VDC, Normal Surge 12VDC to 50VDC, Undervoltage 10VDC, Abnormal 20.5VDC to 32.2VDC and Abnormal Surge to 80VDC.
Voltage Spike: In accordance with Section 17, Category A, 600 volt spikes.
Audio Frequency Conducted Susceptibility: In accordance with Section 18, Category Z.
Induced Signal Susceptibility: In accordance with Section 19, Categories C & Z.
Radio Frequency Susceptibility (Radiated and Conducted): In accordance with Section 20, Category R, high energy radio frequency (HERF) conducted susceptibility 20 V/m, 10 kHz to 400 MHz and radiated susceptibility 20 V/m, 0.1 GHz to 0.4 GHz and 150 V/m (Pulse) 0.4 GHz to 8 GHz.
Emission of Radio Frequency Energy: In accordance with Section 21, Category M conducted RF interference 150 kHz to 30 MHz and radiated RF interference, 2 MHz to 6 GHz.
Lightning Induced Transient Susceptibility: In accordance with Section 22, Category A3XX, waveform 3, 600V/24A and waveform 4, 300V/60A.
Electrostatic Discharge (ESD): Immune to electrostatic discharge, withstanding the 15,000 volt pulse requirements of Section 25 for Category A equipment.
|